《XX住宅小区X楼建筑节能计算文件(2023年).docx》由会员分享,可在线阅读,更多相关《XX住宅小区X楼建筑节能计算文件(2023年).docx(6页珍藏版)》请在第壹文秘上搜索。
1、建筑节能计算文件XX住宅小区X楼工程编号:X建筑专业主持人:(设计总负责人)审定人:校审人:计算人:XX建筑设计有限责任公司2008年X月X日注:1、审定人和计算人不能为同一人2、封面应盖设计单位出图章及节能章一、体形系数计算书(第2页)二、各朝向窗墙比计算书(第24页)三、设计建筑屋顶和外墙保温做法表(表A-I)(第5页)四、参照建筑对比法计算判定表(表A_3)(第6页)1#住宅楼节能计算一、体形系数计算书:体形系数:0.231.外表面积:12584m2293.606x32.45+280x2.95+1485=11838.517m22.体积:50348.65m21485x32.45+666.3
2、4X2.95=50153.95ma3,体形系数:0.2311838.517/50153.95.65=0.23二、各朝向窗墙比计算书1 .南向窗墙比:0.241) .门窗面积:706.78m,门窗面积明细表窗号洞口尺寸(m)每橙面积(m2)槿数(个)面积合计(曲)YTC10221.0x2.22.22044YTC10161.0x1.61.623.2YTC16221.6x2.23.522070.4YTC16161.1x1.62.5625.12YTCl1221.1x2.22.422048.4YTCl1161.1x1.61.7623.52YTC14221.4x2.23.0839120.12YTC1416
3、1.4x1.62.2418.96C15221.5x2.23.3104343.2C15161.5x1.62.41126.4YTC15221.5x2.23.359194.7YTC15161.5x1.62.4614.4YTC17221.7x2.23.7438142.12YTC17161.7x1.62.72410.96YTC1122a1.185x2.22.6072052.14YTCl116a1.185x1.61.89623.792C16221.6x2.23.5213.52FM08230.8x2.31.841018.4C13221.3x2.22.861028.6C09220.9x2.21.981835.
4、64合计706.782).墙面积:2887.655m23).窗墙比:0.24706.78/2887.655=0.242.北向窗墙比:0.21).窗面积:933.19m,门窗面积明细表窗号洞口尺寸(m)每橙面积(of)橙数(个)面积合计(11f)YTC13221.3x2.22.861028.6YTC13161.3x1.62.0812.08C18221.8x2.23.961039.6C18161.8x1.62.8812.88C15221.5x2.23.3145478.5C15161.5x1.62.41536WM15241.5x2.43.6518C05150.5x1.50.752418C17221.
5、7x2.23.7430112.2C17161.7x1.62.7238.16C15191.5x1.92.85552.7156.75C18151.8x1.52.712.7FM08230.8x2.31.84814.72C14151.4x1.52.1510.5C15151.5x1.52.2524.5合计933.192).墙面积:4684.9m23).窗墙比:0.2933.19/4684.9=0.23.西向窗墙比:0.291) .窗面积:258.4面门窗面积明细表窗号洞口尺寸(m)每樟面积(肝)樟数(个)面积合计(肝)C18221.8X2.23.962079.2C18161.8X1.62.8825.76
6、YTC12221.2X2.22.641026.4YTC12161.2X1.61.9211.92C06150.6X1.50.9119.9C09150.9X1.51.351114.85C12221.2X2.22.643079.2C12161.2X2.21.9235.76C15221.5X2.23.31033C15161.5X1.62.412.4合计258.42) .墙面积:888.63) .窗墙比:0.29258.4/888.6=0.294东向窗墙比:0.21).窗面积:204.1IDa门窗面积明细表窗号洞口尺寸(m)每橙面积(m?)橙数(个)面积合计(m?)C15221.5X2.23.33099
7、C15161.5X1.62.437.2C12221.2X2.22.642052.8C12161.2X1.61.9223.84C09150.9X1.51.351114.85C06150.6X1.50.9119.9C07220.7X2.21.541015.4C07160.7X1.61.1211.12合计204.12).墙面积:934.853).窗墙比:0.2204.1/934.85=0.2表A-I设计建筑围护结构做法表围护结构项目做法材料名称厚度(mm)平均传热系数KmW/(m2K)屋顶找坡层(平均)0.41保温层挤塑聚笨板80结构层钢筋混凝土180外墙外保温主体结构钢筋混凝土剪力墙2000.45保温层挤塑聚苯板70内保温主体结构(注:主断面)传热系数)保温层